Sidewall Sprinkel Specification

  • Coating Type
  • Chrome Plated or Brass Finish
  • Shape
  • Rectangular Deflector
  • Operating Pressure
  • Max. 1.2 MPa
  • Technology
  • Glass Bulb Operating Mechanism
  • Mounting Type
  • Wall Mounted (Sidewall)
  • Working Temperature
  • 68C (Standard)
  • Features
  • Fast Response, Corrosion Resistant, Consistent Spray Pattern
  • Coverage Area
  • Up to 2.3m x 4.6m
  • Control Type
  • Automatic
  • Fire Class
  • A, B, C
  • Installation Type
  • Horizontal Sidewall Mount
  • Fire Extinguisher Type
  • Sprinkler
  • Connectivity Type
  • Pipe Threaded Connection
  • Application
  • Fire Fighting System, Wall Mounted Areas, Low Ceiling Spaces
  • Max Flow Rate
  • 80 L/min
  • Diameter
  • 15 mm (1/2 inch)
  • Pressure
  • 1.2 - 1.4 MPa
  • Finish Type
  • Polished / Anti-Corrosive
  • Orifice Size
  • 15 mm
  • Deflector Type
  • Standard Sidewall Deflector
  • Response Type
  • Standard Response
  • Glass Bulb Diameter
  • 5 mm
  • Spacing Requirement
  • Minimum 4 inches below the ceiling
  • Material
  • Brass Body, Heat-Resistant Glass Bulb
  • Weight
  • ~60 grams
  • K-Factor
  • 5.6 US (80 metric)
  • Color Coding
  • Red for 68°C Operating Temperature
 

Sidewall Sprinkel Trade Information

  • Minimum Order Quantity
  • 100 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1000 Units Per Month
  • Delivery Time
  • 7-10 Days
  • Main Domestic Market
  • All India
 

About Sidewall Sprinkel



Introducing the monumental Sidewall Sprinkler, one of our best-sellers and a valuable new release designed for fire safety. Crafted with a solid brass body and a magnificent heat-resistant glass bulb, this innovative device offers a standard response and outstanding corrosion resistance. Its effective sidewall deflector, robust K-factor, and consistent spray pattern ensure maximum protection for wall-mounted areas and low-ceiling spaces. With an automatic, glass bulb operating mechanism, this polished, anti-corrosive sprinkler stands as a valuable asset to any fire fighting system in India.

Exceptional Build and Application Versatility

The Sidewall Sprinkler stands out for its durable brass body paired with a heat-resistant glass bulb, providing excellence in fire fighting applications. Engineered with an advanced glass bulb operating mechanism, it ensures a fast response in emergency situations. This valuable device is best suited for wall-mounted installations, particularly in low ceiling spaces, and delivers a consistent spray pattern essential for Classes A, B, and C fire suppression. Its pipe-threaded connection simplifies installation for a seamless safety upgrade.


Swift Dispatch and Domestic Reach

We meticulously manage dispatching of the Sidewall Sprinkler to ensure quick delivery across key markets in India. Each unit undergoes careful packaging designed for product safety, reflecting our commitment to quality and customer satisfaction. The sale price provides exceptional value for a best-selling, monumental safety solution. Buy with confidence knowing our valuations for delivery are prompt and transparent, ensuring your fire protection needs are met efficiently, whether in commercial, residential, or industrial settings.


FAQ's of Sidewall Sprinkel:


Q: How does the Sidewall Sprinkler operate during a fire emergency?

A: The Sidewall Sprinkler utilizes a heat-resistant glass bulb that activates automatically when the ambient temperature reaches 68C, allowing water to swiftly discharge and suppress fires effectively.

Q: What areas are best suited for installing this sprinkler?

A: This sprinkler is designed for wall-mounted locations, particularly in low ceiling spaces such as corridors, residential apartments, and commercial buildings where ceiling mounting is not feasible.

Q: When should I schedule installation for optimal safety?

A: Installation should be carried out as soon as possible during the final phases of construction or during a safety system upgrade, ensuring uninterrupted fire protection from occupancy onward.

Q: Where should the Sidewall Sprinkler be positioned for maximum efficiency?

A: Install at least 4 inches below the ceiling on sidewalls to ensure the consistent spray pattern covers up to 2.3m x 4.6m, as specified in the product's guidelines for Class A, B, C fire protection.

Q: What is the process for connecting this sprinkler to my system?

A: The sprinkler features a pipe threaded connection for easy integration into most fire fighting networks, ensuring a secure and leak-proof installation.

Q: What are the benefits of choosing this model over standard ceiling sprinklers?

A: This model offers valuable versatility for spaces with structural or aesthetic constraints, as its sidewall mounting and monumental corrosion resistance provide superb protection with minimal intrusion.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Safety Equipmets Category

Pendent Sprinkel

Pendent Sprinkel

Minimum Order Quantity : 10 Units

Mounting Type : Ceiling Mount

Shape : Pendent

Technology : Glass Bulb Heat Sensing

Coating Type : Chrome Plated / Brass

Control Type : Automatic

Hydrant Valve

Hydrant Valve

Minimum Order Quantity : 1 Unit

Mounting Type : Surface Mounted

Shape : Angular (Single Headed)

Technology : Conventional Valve Mechanism

Coating Type : Red Epoxy Powder Coated / Painted

Control Type : Manual Lever

Hose Reel

Hose Reel

Minimum Order Quantity : 10 Units

Mounting Type : Fixed Wall Mount

Shape : Circular Reel

Technology : Manual Rewind

Coating Type : Red Powder Coated

Control Type : Hand Operated Valve

Single Door Hose Box

Single Door Hose Box

Minimum Order Quantity : 100 Units

Mounting Type : Wall mounted

Shape : Rectangular box

Technology : Manual storage enclosure

Coating Type : Red powder coated / Paint coated

Control Type : Manual door opening



Back to top