Double Outlet Landing Valve
Double Outlet Landing Valve

Double Outlet Landing Valve

MOQ : 100 Units

Double Outlet Landing Valve Specification

  • Operating Pressure
  • Up to 12 kgf/cm
  • Coating Type
  • Red Painting/Epoxy Coating
  • Voltage
  • Not Required (Manual)
  • Technology
  • Conventional Valve Mechanism
  • Installation Type
  • Standpipe/Wall Mounted
  • Fire Class
  • Class A & B (General Fire Protection)
  • Features
  • Double Outlet, Rugged Construction, Corrosion Resistant, Easily Operable
  • Mounting Type
  • Vertical/Horizontal Mounting
  • Connectivity Type
  • Flanged/Threaded End
  • Fire Extinguisher Type
  • Wet Riser System
  • Working Temperature
  • Up to 55C
  • Shape
  • Tee (Double Outlet)
  • Coverage Area
  • Dependent on Hose and Nozzle Selection
  • Control Type
  • Manual Operation
  • Application
  • Fire Hydrant System, Fire Protection
  • Max Flow Rate
  • 900 LPM
  • Capacity
  • Dual Hose Outlet
  • Diameter
  • 63 mm (Inlet) x 2 x 63 mm (Outlet)
  • Pressure
  • Tested at 21 kgf/cm (Hydrostatic)
  • Outlet Connection
  • Standard 63 mm Female Instantaneous Coupling as per IS: 903
  • Application Standard
  • Suitable for use in hydrant systems for buildings and industrial firefighting systems
  • Finish
  • Red Painted, Epoxy or Powder Coated
  • Inlet Connection
  • Flanged as per IS: 1538
  • Weight
  • Approx. 14-18 kg
  • Handle Material
  • Stainless Steel/Brass Wheel
  • Body Material
  • Gun Metal/Brass/Stainless Steel
  • Conformance Standard
  • IS: 5290 Type B
 

Double Outlet Landing Valve Trade Information

  • Minimum Order Quantity
  • 100 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 1000 Units Per Month
  • Delivery Time
  • 7-10 Days
  • Main Domestic Market
  • All India
 

About Double Outlet Landing Valve



Redeem safety and peace of mind with our Double Outlet Landing Valve-an opulent addition to any hydrant system. Built from meritorious gun metal, brass, or stainless steel, this breathtaking valve is certified to IS: 5290 Type B and delivers a maximum flow rate of 900 LPM. Its rugged, corrosion-resistant construction and special dual outlet ensure optimal fire protection in industrial and building applications. Order today for unmatched reliability, easily operable design, and a striking red, epoxy, or powder-coated finish that stands the test of time.

Specific and General Uses of Double Outlet Landing Valve

The Double Outlet Landing Valve is precisely engineered for integration in fire hydrant systems, supporting both specific and general fire protection needs. Suitable for buildings and industrial facilities, its use type spans fire protection, wet riser systems, and Class A & B firefighting. With easy manual control and durable construction, it is ideal for commercial and residential hydrant installations, ensuring rapid, dependable water supply in emergencies.


Packaging, Sample Policy, and Export Market Reach

Each Double Outlet Landing Valve is meticulously packaged for safe transport, ensuring pristine delivery through domestic and international transport services. Sample policies are tailored for manufacturers, suppliers, and traders seeking product assurance. Our export market focuses include Asia, Africa, and the Middle East, with strong presence in the domestic Indian mar. We ensure superior service and support for all regional and global clients, meeting diverse installation needs effectively.


FAQ's of Double Outlet Landing Valve:


Q: How is the Double Outlet Landing Valve installed?

A: The valve can be mounted vertically or horizontally on standpipe or wall setups, using flanged or threaded ends for secure attachment in hydrant systems.

Q: What materials are used in the Double Outlet Landing Valve construction?

A: The valve is crafted with premium gun metal, brass, or stainless steel, while the handle is made of stainless steel or brass for lasting durability.

Q: When should this valve be used in a fire system?

A: This landing valve is essential in fire hydrant and wet riser systems where dual hose outlets and manual operation are required for quick fire response.

Q: Where is the Double Outlet Landing Valve most suitable for installation?

A: It is ideal for building fire protection networks, industrial firefighting systems, and any application requiring Class A & B fire protection.

Q: What is the process for maintaining the Double Outlet Landing Valve?

A: Routine inspection for leaks, cleaning, and periodic pressure testing are recommended to maintain optimal functionality and longevity.

Q: What are the benefits of using this valve in hydrant systems?

A: Its double outlet design, robust construction, corrosion resistance, and easy operability provide enhanced safety, reliability, and efficient fire response.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Safety Equipmets Category

Branch Pipe With Nozzle

Branch Pipe With Nozzle

Minimum Order Quantity : 100 Units

Control Type : Manual hand control

Working Temperature : 10C to 55C

Application : Firefighting, water discharge

Shape : Cylindrical with tapered nozzle

Technology : Jet/Spray nozzle technology

Hose Reel

Hose Reel

Minimum Order Quantity : 10 Units

Control Type : Hand Operated Valve

Working Temperature : Up to 60C

Application : Fire Safety and Protection

Shape : Circular Reel

Technology : Manual Rewind

Single Door Hose Box

Single Door Hose Box

Minimum Order Quantity : 100 Units

Control Type : Manual door opening

Working Temperature : Suitable for outdoor and indoor use, generally 10C to +55C

Application : Fire Safety Suitable for storing fire hoses and hose nozzles

Shape : Rectangular box

Technology : Manual storage enclosure

Double Door Hose Box

Double Door Hose Box

Minimum Order Quantity : 1 Unit

Control Type : Manual

Working Temperature : 20C to +55C

Application : Fire Safety, Emergency Hose Storage

Shape : Rectangular Cabinet

Technology : Standard Manual Hose Reel Storage



Back to top